424/641 Bosch Rexroth AG | Tightening Technology 3 608 878 300
System 350 | 3 608 878 300/2019-03
MID 0521 Upload change socket
MID 0521 revision 001
Sent by: Tightening controller
There has been a socket change in the socket tray, i.e. it was removed or inserted.
Note: -
Revision:
001 (supported by Rexroth OP and Rexroth OP-BMW)
Data field: Parameter IDs and parameter values, 24 bytes
Possible response MID Error no. Comment
Acknowledgement upload change
socket
0522 –
Table 6–119: MID 0521 revision 001
Parameter Comments Bytes
Tray 1 Defines the status of the socket in the tray 1.
ID 01
2
Value range – 0 (socket in tray)
– 1 (socket not in tray)
– 2 (socket not used)
Presetting -
Example:
Tray 1 Socket slot not used
Value 2
1
Tray 2 Defines the status of the socket in the tray 2.
ID 02
2
Value range – 0 (socket in tray)
– 1 (socket not in tray)
– 2 (socket not used)
Presetting -
Example:
Tray 2 Socket in tray
Value 0
1
Tray 3 Defines the status of the socket in the tray 3.
ID 03
2
Value range – 0 (socket in tray)
– 1 (socket not in tray)
– 2 (socket not used)
Presetting -
Example:
Tray 3 Socket in tray
Value 0
1
Tray 4 Defines the status of the socket in the tray 4.
ID 04
2
Value range – 0 (socket in tray)
– 1 (socket not in tray)
– 2 (socket not used)
Presetting -
Example:
Tray 4 Socket in tray
Value 0
1