3 608 878 300 Tightening Technology | Bosch Rexroth AG 425/641
System 350 | 3 608 878 300/2019-03
Example:
The examples mentioned in revision 001 would result in the following data field entry:
012020030040051060071080
MID 0522 Acknowledgement upload change socket
Tray 5 Defines the status of the socket in the tray 5.
ID 05
2
Value range – 0 (socket in tray)
– 1 (socket not in tray)
– 2 (socket not used)
Presetting -
Example:
Tray 5 Socket not in tray
Value 1
1
Tray 6 Defines the status of the socket in the tray 6.
ID 06
2
Value range – 0 (socket in tray)
– 1 (socket not in tray)
– 2 (socket not used)
Presetting -
Example:
Tray 6 Socket in tray
Value 0
1
Tray 7 Defines the status of the socket in the tray 7.
ID 07
2
Value range – 0 (socket in tray)
– 1 (socket not in tray)
– 2 (socket not used)
Presetting -
Example:
Tray 7 Socket not in tray
Value 1
1
Tray 8 Defines the status of the socket in the tray 8.
ID 08
2
Value range – 0 (socket in tray)
– 1 (socket not in tray)
– 2 (socket not used)
Presetting -
Example:
Tray 8 Socket in tray
Value 0
1
Data length revision 001
24
Table 6–119: MID 0521 revision 001
Parameter Comments Bytes
Sent by: superordinate computer
The superior computer acknowledges the socket change (socket change upload, MID 0521).
Note: -
Revision:
001 (supported by Rexroth OP and Rexroth OP-BMW)
Data field: is empty, 0 bytes
Possible response: none