430/641 Bosch Rexroth AG | Tightening Technology 3 608 878 300
System 350 | 3 608 878 300/2019-03
MID 0571 revision 001
MID 0573 Select job number
MID 0573 revision 001
Possible response MID Error no. Comment
Command accepted 0005 –
Command error 0004 98 Request timeout in the control or PLC signal not
assigned in the PLC assignment table.
Table 6–123: MID 0571 revision 001
Parameter Comments Bytes
Job start status Defines the status of the job start
The value consists of three ASCII characters.
ID 01
2
Value range – 0 (deactivated)
– 1 (activated)
Presetting -
Example
Tightening
channel number
1
Value 1
1
Data length revision 001
3
Sent by: superordinate computer
This command can be used to select the job number of the tightening channel.
Note: In the PLC assignment table, the Job <n> signal must be applied to the OP module (OP 5.0 - OP 5.7).
Revision: 001 (supported by Rexroth OP and Rexroth OP-BMW)
Data field: 3 bytes
Possible response MID Error no. Comment
Command accepted 0005 –
Command error 0004 98 Request timeout in the control or PLC signal not
assigned in the PLC assignment table.
Table 6–124: MID 0573 revision 001
Parameter Comments Bytes
Job number Number of the job.
The value consists of three ASCII characters.
ID -
Value range 000–999
Presetting -
Example
Job number 001
Value 001
3
Data length revision 001
3