430/641 Bosch Rexroth AG | Tightening Technology 3 608 878 300
System 350 | 3 608 878 300/2019-03
MID 0571 revision 001
MID 0573 Select job number
MID 0573 revision 001
Possible response MID Error no. Comment
Command accepted 0005
Command error 0004 98 Request timeout in the control or PLC signal not
assigned in the PLC assignment table.
Table 6–123: MID 0571 revision 001
Parameter Comments Bytes
Job start status Defines the status of the job start
The value consists of three ASCII characters.
ID 01
2
Value range 0 (deactivated)
1 (activated)
Presetting -
Example
Tightening
channel number
1
Value 1
1
Data length revision 001
3
Sent by: superordinate computer
This command can be used to select the job number of the tightening channel.
Note: In the PLC assignment table, the Job <n> signal must be applied to the OP module (OP 5.0 - OP 5.7).
Revision: 001 (supported by Rexroth OP and Rexroth OP-BMW)
Data field: 3 bytes
Possible response MID Error no. Comment
Command accepted 0005
Command error 0004 98 Request timeout in the control or PLC signal not
assigned in the PLC assignment table.
Table 6–124: MID 0573 revision 001
Parameter Comments Bytes
Job number Number of the job.
The value consists of three ASCII characters.
ID -
Value range 000–999
Presetting -
Example
Job number 001
Value 001
3
Data length revision 001
3