MID 0556 Last job results data acknowledgement
MID 0557 Cancel last job results data
6.7.7.19 Job messages
MID 0570 Activate job
MID 0570 revision 001
MID 0571 Start job sequence
Sent by:
superordinate computer
Last job results data acknowledgement
Note: -
Revision: 001 (supported by Rexroth OP and Rexroth OP-BMW (only with CS))
Data field: is empty, 0 bytes
Possible response: none
Sent by: superordinate computer
Reset the subscription for the last job result.
Note: -
Revision: 001 (supported by Rexroth OP and Rexroth OP-BMW)
Data field: is empty, 0 bytes
Possible responses MID Error no. Comment
Command accepted 0005 –
Command error 0004 10 Activation for the last job result not available
Sent by: superordinate computer
This command can be used to enable the job function of the tightening channel.
Note: In the PLC assignment table, the Job Enable signal must be applied to the OP module (OP 4.6).
Revision: 001 (supported by Rexroth OP and Rexroth OP-BMW)
Data field: 1 byte
Possible response MID Error no. Comment
Command accepted 0005 –
Command error 0004 98 Request timeout in the control or PLC signal not
assigned in the PLC assignment table.
Table 6–122: MID 0570 revision 001
Parameter Comments Bytes
Job status Defines the status of the job.
The value consists of one ASCII character.
ID 01
2
Value range – 0 (deactivated)
– 1 (activated)
Presetting -
Example
Job status deactivated
Value 0
1
Data length revision 001
3
Sent by: superordinate computer
This command can be used to start the job function of the tightening channel.
Note: In the PLC assignment table, the Job Start signal must be applied to the OP module (OP 4.7).
Revision: 001 (supported by Rexroth OP and Rexroth OP-BMW)
Data field: 3 bytes