3 608 878 300 Tightening Technology | Bosch Rexroth AG 463/641
System 350 | 3 608 878 300/2019-03
Description Text maximally 255
characters
– Admissible character set: 7-bit
US ASCII (no umlauts)
This field may remain empty so
that the description can later be
assigned to this AFO at the
server. In this case, you can
then e.g. create country-
specific descriptions with
umlauts.
Graph filter List (expandable) – no graph
– only OK graph
– only NOK graph
– OK and NOK
graph
only NOK graph Determination for which results
the graphs are to be transmitted
OK graph List (expandable) – Last step
–All steps
– Docu steps +
result step
Last step Determination how the graph is
to be transmitted to the IPM
system in case of OK
–Last step
Graph range of the last
tightening step
– All steps
Entire tightening graph
–Docu steps
The corresponding graph
area will be assigned and
transferred for each
completed docu step. Each
step that is transferred to
the IPM system contains the
related graph area.
NOK graph List (expandable) – Last step
–All steps
– Docu steps +
result step
All steps Determination how the graph is
to be transmitted to the IPM
system in case of NOK
–Last step
Graph range of the last
tightening step
– All steps
Entire tightening graph
–Docu steps
The corresponding graph
area will be assigned and
transferred for each
completed docu step. Each
step that is transferred to
the IPM system contains the
related graph area.
Tension relief Option – checked
– not checked
checked – checked
Tension relief range is not
cut off
– not checked
Tension relief range is cut
off
Absolute angle Option – checked
– not checked
not checked If this option is selected, the
graph is converted into a
presentation raising
monotonously with the angle.
Loosen Option – checked
– not checked
not checked If this option is selected, the
tightening is interpreted as
"Loosen".
Table 6–144: Definition of the work sequences (AFO-lines) in the view configuration Rexroth IPM Protocol
Element Type Value range Standard value Comment