EasyManua.ls Logo

Bosch Rexroth Tightening System 350 - Page 462

Bosch Rexroth Tightening System 350
641 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
462/641 Bosch Rexroth AG | Tightening Technology 3 608 878 300
System 350 | 3 608 878 300/2019-03
AFO
Each work sequence (AFO) is represented by one line in the AFO table, see table 6–144. In the AFO
table, an unlimited number of AFOs can be inserted and deleted. It is checked by a mechanism if the
names of several AFOs are identical or if the corresponding field is empty:
AFOs have identical names
In this case, a message is shown that the name has been assigned several times. Moreover, the user
is asked if the name of the AFO is to be changed.
If the user decides to change the name, the cursor is moved to the AFO field (see table 6–144)
and the name can be changed.
If the user decides not to change the name, the name that has been assigned several times is kept.
AFOs have no names
In this case, the following message is output: The configuration contains AFOs with empty names.
Do you still want to continue? Users can choose between Yes and No.
Table 6–144 is a schematic presentation of a clear assignment of the combination of channel number
and program number ("physical process information") to a work sequence ("logic IPM feature").
Table 6–144: Definition of the work sequences (AFO-lines) in the view configuration Rexroth IPM Protocol
Element Type Value range Standard value Comment
Active
1
Option checked
not checked
checked checked
Data is forwarded to the IPM
gateway.
not checked
Data with this channel/
program number is not
forwarded to the IPM
gateway.
Applications:
AFO is defined, however not
activated:
This option is used if the
transmission of the results is
to be avoided, e.g. loosen
processes.
Tightening program not
defined in the AFO list is
tightened:
An AFO (AFO name) is
automatically generated and
the tightening result is sent
to the IPM gateway, see
table footnote
1
.
Channel List (expandable) Online mode:
Tightening
channels
configured on
the tightening
system
Offline mode:
all tightening
channels:
Tightening channel on which
the work sequence runs
Prg List (expandable) all tightening
programs
Program number for this
work sequence
AFO Text maximally 30
characters
Name of the work sequence
Admissible character set: 7-bit
US ASCII (no umlauts)

Table of Contents