3 608 878 300 Tightening Technology | Bosch Rexroth AG 505/641
System 350 | 3 608 878 300/2019-03
"FTP" transmission type
Directory have to start with "\". Directories have to be already available on the target server. Otherwise,
no data is transmitted.
"NFS" transmission type
Directory have to start with "\". Directories have to be already available on the target server. Otherwise,
no data is transmitted.
6.13.2.2 Configuration of directories and ID codes
The configuration for directories and ID codes is realized via the following elements:
"Select ID-code filter ..." dialog
In this dialog, the part serial number from the ID code, the position and the part number (K1001) can be
extracted.
Table 6–185: Elements of "FTP" transmission type
Element Description
Target server IP address for the FTP server.
Port TCP/IP port for data transfer.
Users User name for FTP server access.
The user name has to exist on the FTP server enabling access for data transmission.
Password Password for FTP server access.
The password has to exist on the FTP server enabling access for data transmission.
Table 6–186: Elements of "NFS" transmission type
Element Description
Connection attempts Number of repeated attempts
Target server IP address of the target server.
Server share Has to start with "\".
UserID Has to be identical to the configuration on the target server.
GroupID Has to be identical to the configuration on the target server.
Table 6–187: Configuration of directories and ID codes
Element Description
Path Dfq Directory at which the data sets are saved under the name *.dfq. The path name has
to start with "\" and already be available on the server.
Path Csv Directory at which the graph data is saved under the name *.csv.
ID-code settings As of version V2.500 of the Rexroth Tightening System 350: Via the button, the
Select ID-code filter ... dialog is opened, see (page 505).