552/641 Bosch Rexroth AG | Tightening Technology 3 608 878 300
System 350 | 3 608 878 300/2019-03
Fig. 7–15: Compact system CS351S-G with configured tightening channel
Using the compact system (CS), the transducer function motor current ("Off", "Primary", "Redundancy")
can be configured, whereas the following restrictions apply:
ErgoSpin configuration with adapter, straight output drive or angle head
1. Double click the field highlighted in red to open the associated parameter dialog.
Figure 7–16 shows the dialog Adapter after double clicking the red field in line A.
Table 7–12: Compact system CS351 - Setting the transducer function motor current
Transducer function via
motor current
CS351E-D/IL
CS351E-G/IL
CS351E-G+
CS351E-D NK
CS351S-D/IL
CS351S-G/IL
CS351S-D NK
CC-CS351E-D
Off - x -
Primary
1
1 The compact system can be used for current-controlled tightenings. That means that the motor current can
be used for the primary measurement ("Primary").
-xx
Redundancy
2
2 With the compact system, the motor current can be used for the redundancy measurement.
xx-