3 608 878 300 Tightening Technology | Bosch Rexroth AG 555/641
System 350 | 3 608 878 300/2019-03
Channel
configuration of open
flat output drives
BS350 allows for simple configuration of the ErgoSpin hand-held nutrunner with open flat output drives.
Using the Flat output drive (F) parameter dialog (the symbol is shown in Figure 7–18) select the output
drive spin direction and reverse spin direction. Depending on these two settings, the alignment spin
direction of the motor is adjusted accordingly. In this way, you can use flat output drives with
counterclockwise spin direction and flat output drives with clockwise spin direction.
"Referencing
Fig. 7–18: Channel configuration: Symbol flat output drive (F)
Table 7–13 describes the parameters that you can set in the Flat output drive (F) parameter dialog.
Table 7–13: Parameter for setting the flat output drive (F)
Parameter Description
Code With flat output drives, there is no selection option. The component is displayed
with the corresponding serial number as soon as you accept the configuration.
Order number Component order number
Serial number Component serial number
Efficiency Specification of efficiency in percent [%]
Value range: 0% 100%
Transmission Specification of the transmission
Value range: 0 1.000
Max. torque Maximum torque up to which the flat output drive may be used
Reverse spin direction Specification of an option for a reverse spin direction
–Activated
Select this option if the drive spin direction of the flat output drive does not
correspond to the output drive spin direction of the flat output drive.
Deactivated
Select this option if the drive spin direction of the flat output drive
corresponds to the output drive spin direction of the flat output drive.
Output drive spin direction Specification of the mechanically defined spin direction / tightening direction
(spin direction not running towards the safety catch) of the flat output drive
Value range:
Counterclockwise
Clockwise
Cycle counter Cycles that have already been run through on the flat output drive.
Presetting: 0
Open flat key program-controlled This parameter is available for flat output drives without safety catch as of
Rexroth Tightening System V2.400.
Activate this option for configuration of the open flat output drive without safety
catch. After sending, the system is restarted.
Precise motor screw reduction
ratio
This parameter is available for flat output drives without safety catch as of
Rexroth Tightening System V2.400.
Specification of the accuracy for the reduction ratio of the motor screw. For open
position accuracy, the value should be entered with 12 decimal places. See also
table 7–14.
Change component Click on this button in case of a component change to save the serial number
and the number of cycles of the new component.