560/641 Bosch Rexroth AG | Tightening Technology 3 608 878 300
System 350 | 3 608 878 300/2019-03
7.5.2.4 Setting up installed interfaces
Serial interfaces X3C1
This serial interface is intended to connect a printer or scanner.
Open the associated parameters dialog by double clicking the parameter field in line X3C1 (see Figure
7–14).
Fig. 7–19: Parameter dialog X3C1
You can make the following settings in the Set up serial interface group:
• Baud rate (300, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200)
The presetting is 115200 Baud. Use this value, if the partner controller allows so. Otherwise, delays
during results output may occur, which limits the availability of the system.
• Data bits (7, 8)
• Parity (none, odd, even)
• Stop bits (0, 1, 2) and
• Protocol (none, X-On/X-Off, RTS/CTS).
Click Accept to store these data in the program.
Ethernet interface X7E1
The installed Ethernet interface is used for tightening results output and for programming the tightening
controller.
The associated parameter dialog is opened by double clicking the parameter field in line X7E1 (see Figure
7–14):
Fig. 7–20: Parameter dialog X7E1