You can make the following settings in the Ethernet interface setup group:
IP address: Assigned by the network administrator; identifies the participant in the data exchange.
Subnet mask: Assigned by the network administrator; contains information on the network
configuration (address range).
Host name: Name by which the Ethernet participant (here the compact system/the KE of the
tightening system) can be addressed.
DNS: Assignment of logical participant names to unique IP addresses.
Domain name: The domain name is the same for all the participants in an Ethernet, the full logical
name of a participant is Hostname@Domainname.
Gateway: Establishes the external connection.
Click Accept to store these data in the program.
Click Accept to store the data in the program.
7.5.2.5 Setting up additional interfaces
Type A interface modules
This interface is intended for inserting type A interface modules from Rexroth. A tightening system is
controlled by this interface.
Open the associated parameter dialog by double clicking the parameter field in line A (see Figure 7–14).
In the Select interface module field, select the desired module from the drop-down list and set its
parameters.
General parameters for all interfaces
Physical interface The physical characteristics of the interface depend on the field bus module used. They can only be
partially configured via the operating system.
Number of I points /
Number of O points
This parameter determines how many control signals should be processed via the field bus interface.
Receive data / Send
data
Setting of the remaining data width. These settings depend on the set scope of the I/O points. If the
maximum available bandwidths are exceeded, the settings will be automatically corrected to correspond
to the maximum data width. Make sure that the receipt range for ID codes is also set here.
The allocation of the data buffer is shown in tables in section Layout of the data buffer for transferring
ID-codes and results data (see page 291).
Receive IL data /
Send IL data
Only with KE350G IL and CS351x-IL: Setting of the remaining data width. These settings depend on the
set scope of the I/O points. If the maximum available bandwidths are exceeded, the settings will be
automatically corrected to correspond to the maximum data width.
Detailed information on the data exchange via Ethernet can be found under Ethernet communication
(page 214)!
This setting only reserves the memory space for the logical control signals (1 bit per input or output).
Control signal assignment is implemented using the PLC assignment table.
The indicated value ranges are maximum values that can only be fully used if the other parameters have
not been set to the maximum value.