16 Sync Scorer Components
(8) Camera Port Power (JP19) - Selects voltage level used for the cameras.
Install jumpers at pins 2-3 (+12V).
(9) LAN3 Communication Type (JP20) - Determines the communication protocol used for LAN3
(J18).
Default - Install jumper at pins 2-3 (RS232)
Intellishield controller connected to LAN3 - Install jumper at pins 1-2 (RS485)
(10) Reset - (SW1) Push button used to restart the Distribution board.
(11) Digital Camera Enable - (JP8) Factory use only.
JP8 - Install Jumper (Default)
(12) MemoryConguration - (JP14,JP15) Factory use only.
JP14 - Install jumper at pins 1-2 (Default)
JP15 - Install jumper at pins 1-2 (Default)
(13) Board Address 2 - Factory use only. Always set switch 8 to the ON position. Setting the
switch to the OFF position will place the board into a factory test mode and cause diagnostics
LED, D36 to ash rapidly.