Some conditions cause a warning message, without fault activation:
Warning Message Cause Action
Detect.inhibited
The Metal Detector is inhibited by
external device connected to the
INHIBITION input
If the Metal Detector remain continuously inhibited, check
the INHIBITION input line functioning.
TRANSMISSION OFF
Transmission has been disabled.
This function will be automatically enabled at the system
reboot or by manually reactivating the relevant parameter.
EJECTION OFF
The Metal Detector ejection system
has been disabled.
This function will be automatically enabled at the system
reboot or by manually reactivating the relevant parameter.
MUST BE ON
Ejection is disabled at Test start-up Activate the ejection system, before starting a Test
WARN: IXC timeout
IXC card disconnected or damaged
Check the IXC card connection to the ALM card.
Switch the Metal Detector off and on.
If the problem persists, contact Assistance Service.
EJECTION
IN PROGRESS
Previous ejection not concluded at
Test start-up
In ejection mode with belt stop, complete the ejection
before starting a Test.
AUTOLEARN ABORTED
TA Autolearn aborted
Check the absence of noise or vibrations during the
procedure and repeat it. If the procedure is aborted
because of a fault, check the message on the display.