SLM-5650B Satellite Modem
Revision 2
Appendix C C–26 MN-SLM-5650B
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to
Query
Rx
Reed-Solomon
Code Word
RCW= 1 byte Command or Query.
Rx RS encoding in the form x, where:
0 = RS(225,205,10)
1 = RS(219,201,9)
2 = RS(208,192,8)
3 = RS(194,178,8)
4 = RS(126,112,7)
5 = RS(220,200,10)
Depending on Modem mode, overhead type, and data rate, not all
selections will be valid.
Example: RCW = 0 (This is a ‘don’t care’ if RS is Off under TRS)
RCW =
RCW?
RCW *
RCW #
RCW? RCW=x
(see Description
of Arguments)
Rx Differential
Decoding
RDD= 1 byte Command or Query.
Rx Differential Decoding in the form x, where:
0 = Off
1 = On
Depending on FEC type or Modulation Type, not all selections will be
valid.
Example: RDD = 1 (selects Rx Differential Decoding On)
RDD=
RDD?
RDD*
RDD#
RDD? RDD=x
(see Description
of Arguments)
Rx Data Fault
RDF=
1 byte
Command or Query.
Receive Data Fault, where:
0 = None
1 = DATA
2 = AIS
Example: RDF = 0 (selects Data Fault = None)
RDF =
RDF?
RDF*
RDF#
RDF?
RDF=x
(see Description
of Arguments)
Rx Data Invert
RDI=
1 byte
Command or Query.
Invert Receive Data, where:
0 = Normal
1 = Inverted
Example: RDI = 1 (selects Inverted RX Data)
RDI =
RDI?
RDI*
RDI#
RDI?
RDI=x
(see Description
of Arguments)