EasyManua.ls Logo

Comtech EF Data SLM-5650B - Bulk Configuration Commands; Queries

Comtech EF Data SLM-5650B
412 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SLM-5650B Satellite Modem
Revision 2
Appendix C C–48 MN-SLM-5650B
C.6.5 Bulk Configuration Commands / Queries
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to
Query
Configuration
Load
CLD=
1 byte
Command only.
Causes the modem to retrieve a previously stored configuration
from Configuration Memory location defined by the one-byte
argument (0 to 9).
Example: CLD = 4 (retrieve modem configuration from location 4)
CLD=
CLD?
CLD*
CLD#
N/A
N/A
Configuration
Save
CST= 1 byte Command only.
Command causes the modem to store the current configuration in
Configuration Memory location defined by the one-byte argument
(0 to 9).
Example: CST = 4 (store the current configuration in location 4)
CST=
CST?
CST*
CST#
N/A N/A
Global
Configuration
MGC= 217 bytes Command or Query.
Global Configuration of SLM-5650B, in the form:
a = Modem Operating Mode same as MOM
b = Modem RF Band same as RFB
c = Modem Interface Type same as ITF
d = Modem Reference Clock same as MRC
eeeee = Modem Alarm Mask same as MSK
f = Carrier Only Test Modes same as COM
g = Loopback Test Modes same as LOP
h = Tx BERT State same as BTX
i = Rx BERT State same as BRX
j = BERT Pattern same as PAT
k = CnC Mode same as CNM
llllll = CnC Mode same as CSD
m = expansion byte
n = Tx FEC Type same as TFT
o = Tx Modulation Type same as TMD
p = Tx Code Rate same as TCR
MGC=
MGC?
MGC*
MGC#
MGC?
MGC=abcdeeeeeef
ghijk
llllllmnopqqqqqq.qq
q
rrrr.rrrrstuvwxyzAB
CCC.C
DEFGHIJKLLMM.M
MM
NOPQQQQQQ.QQ
Q
RRRR.RRRRSTTT
UVW
XYZabcdeeee.eeeff
fgh
Iiiiiiiijj.jklmnopqrsss.
sttt.t
uuu.uvv.vw.wxyzAB
CCD
EEuuuFFFFGGGG

Table of Contents

Related product manuals