EasyManua.ls Logo

Comtech EF Data SLM-5650B - Page 374

Comtech EF Data SLM-5650B
412 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SLM-5650B Satellite Modem
Revision 2
Appendix C C–46 MN-SLM-5650B
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to
Query
Retrieve next 5
unread Stored
Statistics
N/A 105 bytes Query only.
Unit returns the oldest five Stored Statistics which have not yet
been read over the remote control.
Reply format: {CR}Sub-body{CR}Sub-body{CR}Sub-body{CR}Sub-
body{CR}Sub-body, where Sub-body= AA.ABB.Bddmmyyhhmmss,
AA.A = Minimum Eb/No during sample period. “Loss” is displayed
if carrier was lost during the sample period.
BB.B = Average Eb/No during sample period. “Loss” is displayed if
carrier was lost during the entire sample period.
If there are fewer than five events to be retrieved, the remaining
positions are padded with zeros.
If there are no new events, the response is RNS*.
N/A RNS? RNS=
{CR}AA.ABB.B
ddmmyyhhmmss
{CR}AA.ABB.B
ddmmyyhhmmss
{CR}AA.ABB.B
ddmmyyhhmmss
{CR}AA.ABB.B
ddmmyyhhmmss
{CR}AA.ABB.B
ddmmyyhhmmss
(see Description
for Arguments)
Serial Number N/A 9 bytes Query only.
Used to query the unit 9-digit serial number.
Unit returns its S/N in the form xxxxxxxxx.
Example: SNO = 176500143
N/A SNO? SNO=xxxxxxxxx
(see Description
of Arguments)
Statistics Sample
Interval
SSI=
1 byte
Command or Query.
Used to set the sample interval for the Statistics Logging Function.
SSI = x, where x = 0 to 9 in 10 minute steps.
Note: Setting this parameter to 0 disables the statistics logging
function.
Example: SSI = 3 sets the logging inverval to 30 minutes
SSI=
SSI?
SSI*
SSI#
SSI?
SSI=x
(see Description
of Arguments)
Software
Revision
N/A
43 bytes
Query only.
Unit returns the value of the internal software revision installed in
the unit, in the form:
Boot:xx.yy.zz Bulk1:xx.yy.zz Bulk2:xx.yy.zz
Example: SWR = Boot:01.01.01 Bulk1:01.01.01 Bulk2:01.01.01
N/A
SWR?
SWR=
Boot:xx.yy.zz
Bulk1:xx.yy.zz
Bulk2:xx.yy.zz
(see Description
of Arguments)

Table of Contents