14 Genie Nano Specifications Nano Series GigE Vision Camera
EMI, Shock and Vibration Certifications
Compliance Directives Standards ID Overview
CE
EN61000-4-2 : 2008 Electrostatic discharge immunity test
EN61000-4-3 : 2006 A1 : 2007 A2 :
2010
Radiated, radio-frequency, electromagnetic field
immunity test
EN61000-4-4 : 2004 Electrical fast transient/burst immunity test
EN61000-4-5 : 2005 Surge immunity
EN61000-4-6 : 2008
Immunity to conducted disturbances, induced by
radio-frequency fields
EN61000-4-8 : 2009 Power frequency magnetic field immunity
EN61000-4-11 : 2004 Voltage variations immunity
EN61000-6-2 : 2005 Electromagnetic immunity
EN61000-6-4: 2007 Electromagnetic emissions
CISPR 11: 2009 A1 :
group 1 FCC, part 15, subpart B:2010
Limit: class A Conducted Emissions
CISPR 22 : 2008 Limit: class A LAN port Conducted Emissions
FCC
Part 15, class A
RoHS
Compliancy as per European directive 2011/65/EC
See EC & FCC Declarations of Conformity.
Vibration & Shock Tests Test Levels (while operating) Test Parameters
Random vibrations
Level 1: 2 grms 60 min.
Level 2: 4 grms 45 min.
Level 3: 6 grms 30 min.
Frequency range: 5 to 2000 Hz
Directions: X, Y, and Z axes
Shocks
Level 1: 20 g / 11 ms
Level 2: 30 g / 11 ms
Level 3: 40 g / 6 ms
Shape: half-sine
Number: 3 shocks (+) and 3 shocks (-)
Directions: ±X, ±Y, and ±Z axes
Additional information concerning test conditions and methodologies is available on request.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dalsa Genie Nano Series and is the answer not in the manual?

Dalsa Genie Nano Series Specifications

General IconGeneral
BrandDalsa
ModelGenie Nano Series
CategorySecurity Camera
LanguageEnglish

Related product manuals