NOTE
It is recommended that programming sessions be limited to one f
eature
at a time. Should you make a mistake in the programming sequence, it
can be difficult to discover where an error has been made if several fea-
tures are programmed at once. Additionall
y, it can be confusing to deter-
mine which features may or may not have been successfully set following
suc
h a session.
7-6 Magellan
TM
8500Xt Scanner
3. Scan the SWITCH barcode to save any new settings and exit Pro-
gramming Mode. The scanner will so
und a beep and reset upon
exiting Programming Mode, and the green LED will return to its
usual state (on steady or off).
The scanner will exit Programming Mode under the following
condi
tions:
the programming sequence has been completed or the
SW
ITCH barcode is scanned
five minutes have passed without scanning activity. Any data
pr
ogrammed during the current session will be ignored
1
, and
the scanner will reset and revert to its condition previous to
initiating the exited
session.
power is disconnected. Disconnecting power during Pro-
gramming Mode, before scanning the SWITCH barcode,
will cause
all new settings to be ignored. On power-up, the
scanner will return to previous settings.
4. Maintain a good record of all changes made to ensure that you
kno
w if the original factory settings have been changed.
1. Exception: If an interface barcode had been read while in Programming Mode, the scanner will
operate on the default settings for the new interface.

Table of Contents

Other manuals for Datalogic Magellan 8500Xt

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Magellan 8500Xt and is the answer not in the manual?

Datalogic Magellan 8500Xt Specifications

General IconGeneral
TypeBuilt-in bar code reader
Sensor type-
Read rate (max)6400 reads/s
Yaw reading angle0 - 360 °
Linear (1D) barcodes supportedGS1-128 (UCC/EAN-128)
2D (matrix & stacked) barcodes supportedNot supported
Standard interfacesRS-232
Connectivity technologyWired
Input voltage100 - 250 V
Input frequency50 Hz
Power source typeAC
Power consumption (typical)9 W
Product colorGrey, Silver
Sustainability certificatesRoHS
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)10 - 40 °C
Operating relative humidity (H-H)5 - 95 %
Weight and Dimensions IconWeight and Dimensions
Depth127 mm
Width292 mm
Height178 mm
Weight- g

Related product manuals