RS-232 Host Echo Quiet Interval
This setting specifies the time interval of RS-232 channel inactivity which
must transpire before the scanner will break the host echo loop to transmit
the barcode data that has just been scanned to the host.
0 - 100 = Time in 10-millisecond increments.
To set the Host Echo Quiet Interval:
1. Scan the SWITCH barcode.
2. Scan the barcode below, SET RS-232 HOST ECHO QUIET
INTERVAL. You’ll need to cover any unused barcodes on this and
the facing page to ensure that the scanner reads only the barcode
y
ou intend to scan.
3. Scan the appropriate digits from the keypad in
Appendix C that
represent the desired timeout. The selectable range is 0-100,
which
is the timeout in 10-millisecond increments. Pad all single
and double digit numbers with leading zeroes to yield a three-
digit entry (000-100).
Examples:
001 = 10ms
005 = 50ms
040 = 400ms
100 = 1,000ms (1 second)
4. The scanner will automatically exit Programming Mode when the
appr
opriate amount of digits have been scanned.
SET RS-232 HOST ECHO QUIET INTERVAL

Table of Contents

Other manuals for Datalogic Magellan 8500Xt

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Magellan 8500Xt and is the answer not in the manual?

Datalogic Magellan 8500Xt Specifications

General IconGeneral
TypeBuilt-in bar code reader
Sensor type-
Read rate (max)6400 reads/s
Yaw reading angle0 - 360 °
Linear (1D) barcodes supportedGS1-128 (UCC/EAN-128)
2D (matrix & stacked) barcodes supportedNot supported
Standard interfacesRS-232
Connectivity technologyWired
Input voltage100 - 250 V
Input frequency50 Hz
Power source typeAC
Power consumption (typical)9 W
Product colorGrey, Silver
Sustainability certificatesRoHS
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)10 - 40 °C
Operating relative humidity (H-H)5 - 95 %
Weight and Dimensions IconWeight and Dimensions
Depth127 mm
Width292 mm
Height178 mm
Weight- g