1-10 Magellan
TM
8500Xt Scanner
Power Supply
The scanner utilizes a single power supply for all models. Unique installa-
tion and international connections are acc
omplished through selection of
the proper IEC power cord
VOLTAGE FREQUENCY CURRENT (RMS) PART NUMBER
100-240VAC ±10% 50-60 Hz 0.5 Amps @ 100V 8-0761
CAUTION
Safe operation of your scanner or scanning-scale requi
res properly grounded
electrical outlets. Be sure to have a qualified electrician certify the earth-
ground connection on circuits which will be used to power the unit.
NOTE
The scanner is powered on/off by connecting/disconnecting its
AC power
supply.