RS-232 Ignore Host Commands
When set to ignore host commands, the scanner will ignore all host com-
mands except for the minimum set necessary to keep the interface active,
transmit la
bels, and transmit scale information. For normal operation of
the interface, disable this feature.
To set this feature:
1. Scan the SWITCH barcode.
2. Scan your selection from the barcodes below. You’ll need to cover
any unused bar
codes on this and the facing page to ensure that
the scanner reads only the barcode you intend to scan.
3. Complete the programming seque
nce by scanning the SWITCH
barcode.
RS-232 IGNORE HOST COMMANDS = DISABLE
RS-232 IGNORE HOST COMMANDS = ENABLE

Table of Contents

Other manuals for Datalogic Magellan 8500Xt

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Magellan 8500Xt and is the answer not in the manual?

Datalogic Magellan 8500Xt Specifications

General IconGeneral
TypeBuilt-in bar code reader
Sensor type-
Read rate (max)6400 reads/s
Yaw reading angle0 - 360 °
Linear (1D) barcodes supportedGS1-128 (UCC/EAN-128)
2D (matrix & stacked) barcodes supportedNot supported
Standard interfacesRS-232
Connectivity technologyWired
Input voltage100 - 250 V
Input frequency50 Hz
Power source typeAC
Power consumption (typical)9 W
Product colorGrey, Silver
Sustainability certificatesRoHS
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)10 - 40 °C
Operating relative humidity (H-H)5 - 95 %
Weight and Dimensions IconWeight and Dimensions
Depth127 mm
Width292 mm
Height178 mm
Weight- g