EasyManua.ls Logo

Develop ineo 250 - Page 478

Develop ineo 250
770 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Field Service Ver. 1.0 Aug. 2005 11. Soft Switch List
109
FK-503Adjustment / Setting
NOTE
The features with (*) are settable by users. <*>: Soft switch setting
NOTE
The features with (*) are settable by users. <*>: Soft switch setting
MODE Factory setting bit
356
Bit: 7654 3210
0100 0000
HEX:F40
Bit Feature
Logic
Description
01
7 SMTP transmission time-
out (Network function) <*>
Bit 7-4: 0000 Not available Set time waiting for a
response to mail com-
mands from the destina-
tion scanner or the
SMTP server in scanner
transmission or E-mail
transmission.
Effective after the main
power switch is turned
off and on.
6 0001 30 sec
5 0010 60 sec
4 0011 90 sec
0100 120 sec
0101 150 sec
0110 180 sec
0111 210 sec
1000 240 sec
1001 270 sec
1010 300 sec
Others Not available
MODE Factory setting bit
357
Bit: 7654 3210
0100 0000
HEX:40
Bit Feature
Logic
Description
01
7 SMTP transmission time-
out (Network function) <*>
Bit 7-4: 0000 Not available Specify time waiting for
command from SMTP
client.
Valid after the mai pow-
erswitch is turned off
and on.
6 0001 30 sec
5 0010 60 sec
4 0011 90 sec
0100 120 sec
0101 150 sec
0110 180 sec
0111 210 sec
1000 240 sec
1001 270 sec
1010 300 sec
Others Not available

Table of Contents

Related product manuals