8 Instructions for Use Fabius MRI SW 3.n
For Your Safety and that of Your Patients
Strictly follow these Instructions for Use
Maintenance
Accessories
Not for use in areas of explosion hazard
Safe connection with other electrical equipment
Safe networking of computers
When networking with electrical devices, the oper-
ator is responsible for ensuring that the resulting
system meets the requirements set forth by the fol-
lowing standards:
EN 60601-1 (IEC 60601-1)
Medical electrical equipment
Part 1: General requirements for safety
EN 60601-1-1 (IEC 60601-1-1)
Medical electrical equipment
Part 1-1: General requirements for safety
Collateral standard: Safety requirements for
medical electrical systems
EN 60601-1-2 (IEC 60601-1-2)
Medical electrical equipment
Part 1-2: General requirements for safety
Collateral standard: Electromagnetic compati-
bility; Requirements and tests
EN 60601-1-4 (IEC 60601-1-4)
Medical electrical equipment
Part 1-4: General requirements for safety
Collateral standard: Programmable electrical
medical systems
Follow associated Assembly Instructions and
Instructions for Use.
WARNING
Strictly follow these Instructions for Use. Any
use of the medical device requires full under-
standing and strict observation of all portions
of these instructions. The medical device is
only to be used for the purpose specified
under “Intended Use” on page 16 and in con-
junction with appropriate patient monitoring
(see page 9). Strictly observe all WARNING
and CAUTION statements throughout this
Instruction for Use and all statements on
medical device labels.
WARNING
The medical device must be inspected and
serviced regularly by trained service person-
nel.
Repair of the medical device may also only be
carried out by trained service personnel.
Dräger recommends that a service contract be
obtained with DrägerService and that all
repairs also be carried out by them. Dräger
recommends that only authentic Dräger repair
parts be used for maintenance. Otherwise the
correct functioning of the medical device may
be compromised.
See chapter "Maintenance".
WARNING
Only the accessories indicated on the list of
accessories 9052102 enUS (1st edition or hig-
her) have been tested and approved to be
used with the medical device. Accordingly it is
strongly recommended that only these acces-
sories be used in conjunction with the specific
medical device. Otherwise the correct func-
tioning of the medical device may be compro-
mised.
WARNING
This medical device is neither approved nor
certified for use in areas where combustible or
explosive gas mixtures are likely to occur.
WARNING
Electrical connections to equipment which is
not listed in these Instructions for Use should
only be made following consultation with the
respective manufacturers.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dräger Fabius and is the answer not in the manual?

Dräger Fabius Specifications

General IconGeneral
TypeAnesthesia Workstation
DisplayColor TFT
Gas SupplyO2, N2O, Air
CO2 AbsorberYes
ManufacturerDräger
ModelFabius
Ventilation ModesSIMV
Inspiratory Time0.2-5 s
PEEP0 to 20 cmH2O
Vaporizer Mounts2
O2 Flow0 to 15 L/min
Air Flow0 to 15 L/min