Ranger HRC™ operator´s manual – System software
72 Publ. No. TM 614 006 699 Rev B – ENGLISH (EN) – Oct 30. 2008
Setup – Maintenance dialog box
Feature Description
Baudrate The Baudrate feature is used to set the communication speed.
1200 bps
2400 bps
4800 bps
9600 bps
19200 bps
The new Baudrate value will take effect immediately.
NOTE: If the Baudrate is changed, it will take a few button presses or
joystick movements before the JCU is in sync again.
Device ID The Device ID feature is used to set the device ID:
01-31
NOTE: If the 5x0 protocol (see the Protocol feature below) is selected,
the Device ID feature is disabled.
Protocol The Protocol feature is used to select the type of communication protocol:
5x0
TASS
Optional protocols, such as PELCO D, are available on request.
The new protocol setting will take effect immediately.
NOTE: If the protocol is changed, it will take a few button presses or
joystick movements before the JCU is in sync again.
NOTE: As 5x0 is a point-to-point protocol, no Device ID can be
selected.
Change password The Change password feature is used to enter a password or change the
existing password for the Setup – Maintenance dialog box.
Yes: Opens the New password or Change password dialog box, see
section 7.6.1.6.2 and 7.6.1.6.3.
No: No action.

Table of Contents