Ranger HRC™ operator´s manual – System software
Publ. No. TM 614 006 699 Rev B – ENGLISH (EN) – Oct 30. 2008 73
Setup – Maintenance dialog box
Feature Description
IR/TV video swap The IR/TV video swap feature is used to control the video signal.
Yes: The active video signal is swapped between the two video outputs
on the JPC2 when the operator toggles between IR and TV. If two moni-
tors are used, the TV and IR images will move between the monitors.
No: Only the indicator for active channel will move between the monitors.
Default settings The Default setting feature is used to reset parameters, except for example
lists of autoscan points, Baudrate and Protocol, to factory settings.
Yes: The default settings are reset.
No: No action.
Detect devices The Detect devices feature is used to check for system changes and make
required adjustments.
Yes: Opens the Detect devices dialog box, see section 7.6.1.6.4.
No: No action.
MMI Control mode The Joystick Control Unit (JCU) operates with two different settings, with
somewhat different functions for the joystick and the keypad buttons, see
section 6.2.1.
The
MMI Control mode feature is used to select the JCU setting.
Original
Alternative
NOTE: Another commonly used term corresponding to MMI (Man
Machine Interface) is GUI (Graphical User Interface).

Table of Contents