5.2 Function Codes Table
5-31
FUNCTION CODES
Chap 5
Code Name Data setting range
Change when running
Data copying
Factory
Default
Drive control
Related page
V/f
PG V/f
w/ PG
Torque control
PM
U71
Customizable logic
(Output selection)
Output signal 1
0: Disable
1 to 200: Output of Step 1 to 200 S001to S0200
N
Y
0
Y
Y
Y
Y
Y
U72
Output signal 2
N
Y
0
Y
Y
Y
Y
Y
U73
Output signal 3
N
Y
0
Y
Y
Y
Y
Y
U74
Output signal 4
N
Y
0
Y
Y
Y
Y
Y
U75
Output signal 5
N
Y
0
Y
Y
Y
Y
Y
U76
Output signal 6
N
Y
0
Y
Y
Y
Y
Y
U77
Output signal 7
N
Y
0
Y
Y
Y
Y
Y
U78
Output signal 8
N
Y
0
Y
Y
Y
Y
Y
U79
Output signal 9
N
Y
0
Y
Y
Y
Y
Y
U80
Output signal 10
N
Y
0
Y
Y
Y
Y
Y
U81
Customizable logic
(Function selection)
Output signal 1
0 to 172 (1000 to 1172): Same as E01
8001 to 8020: The value with 8000 added to E61
N
Y
100
Y
Y
Y
Y
Y
U82
Output signal 2
N
Y
100
Y
Y
Y
Y
Y
U83
Output signal 3
N
Y
100
Y
Y
Y
Y
Y
U84
Output signal 4
N
Y
100
Y
Y
Y
Y
Y
U85
Output signal 5
N
Y
100
Y
Y
Y
Y
Y
U86
Output signal 6
N
Y
100
Y
Y
Y
Y
Y
U87
Output signal 7
N
Y
100
Y
Y
Y
Y
Y
U88
Output signal 8
N
Y
100
Y
Y
Y
Y
Y
U89
Output signal 9
N
Y
100
Y
Y
Y
Y
Y
U90
Output signal 10
N
Y
100
Y
Y
Y
Y
Y
U91
Customizable logic timer
monitor (Step selection)
0: Monitor disable
1 to 200: Step 1 to 200
Y
N
0
Y
Y
Y
Y
Y
U92
Customizable logic
(The coefficients
of the
approximate formula)
(Mantissa of KA1)
-9.999 to 9.999
N
Y
0.000
Y
Y
Y
Y
Y
U93
(Exponent part of KA1)
-5 to 5
N
Y
0
Y
Y
Y
Y
Y
U94
(Mantissa of KB1)
-9.999 to 9.999
N
Y
0.000
Y
Y
Y
Y
Y
U95
(Exponent part of KB1)
-5 to 5
N
Y
0
Y
Y
Y
Y
Y
U96
(Mantissa of KC1)
-9.999 to 9.999
N
Y
0.000
Y
Y
Y
Y
Y
U97
(Exponent part KC1)
-5 to 5
N
Y
0
Y
Y
Y
Y
Y
U100
Task process cycle setting
0: Auto select from 2, 5, 10 or 20 ms depending on the
number of steps
2: 2 ms (Up to 10 step)
5: 5 ms (Up to 50 step)
10: 10 ms (Up to 100 step)
20: 20ms (Up to 200 step) *5
N
Y
0
Y
Y
Y
Y
Y
U101
Customizable logic
(Operating point 1 (X1))
-999.00 to 0.00 to 9990.00
Y
Y
0.00
Y
Y
Y
Y
Y
5-250
5-273
U102
(Operating point 1 (Y1))
Y
N
Y
Y
Y
Y
Y
U103
(Operating point 2 (X2))
Y
N
Y
Y
Y
Y
Y
U104
(Operating point 2 (Y2))
Y
N
Y
Y
Y
Y
Y
U105
(Operating point 3 (X3))
Y
N
Y
Y
Y
Y
Y
U106
(Operating point 3 (Y3))
Y
N
Y
Y
Y
Y
Y
U107
Customizable logic
(
Auto calculation of the
coefficients
of the
approximate formula)
0: Invalid
1: Execute calculation
(When the calculation is finished, the results are stored
to the function code U92 to U97)
N
N
0
Y
Y
Y
Y
Y
5-250