5.3 Description of Function Codes
5-131
FUNCTION CODES
Chap 5
E43
LED monitor (Item selection)
Related function code: E48 LED monitor (speed monitor item)
E43 specifies the running status item to be monitored and displayed on the LED monitor.
Specifying the speed monitor with E43 provides a choice of speed-monitoring formats selectable with E48 (LED
monitor).
Monitor item
Display
sample on
the LED
monitor
LED indication Unit Meaning of displayed value E43 data
Speed monitor
Function code E48 specifies what to be displayed on the LED monitor and LED
indicators.
0
Output frequency 1
(before slip
compensation)
5*00
HzAkW Hz Indicated value = Output frequency (Hz) (E48 = 0)
Output frequency 2
(after slip
compensation)
5*00
HzAkW Hz Indicated value = Output frequency (Hz) (E48 = 1)
Reference frequency
5*00
HzAkW Hz Indicated value = Reference frequency (Hz) (E48 = 2)
Motor rotation speed
1500
HzAkW min
-1
P01
120
(Hz)frequency Outputvalue Indicated ×=
(E48 = 3)
Load rotation speed
30*0
HzAkW min
-1
Indicated value = Output frequency (Hz) × E50 (E48 = 4)
Line speed
30*0
HzAkW m/min
Indicated value = Output frequency (Hz) × E50 (E48 = 5)
Transport time for
specified length
5*00
HzAkW min Indicated value = E50/(Output frequency × E39) (E48 = 6)
Speed (%)
5*0
HzAkW %
100
frequency Maximum
(Hz)frequency Output
value Indicated ×=
(E48 = 7)
Output current
1"34
HzAkW A Current output from the inverter in RMS 3
Output voltage
200u
HzAkW V Output voltage (RMS) of the inverter 4
Calculated torque
50
HzAkW % Motor output torque in % (Calculated value) 8
Input power
1*25
HzAkW kW Input power to the inverter 9
PID process command
1*0*
HzAkW -
PID command and its feedback converted into
physical quantities of the object to be controlled
(e.g. temperature)
10
PID feedback value
)0*
HzAkW - 12
Timer value
100
HzAkW s Timer value (remaining run time) 13
PID output
10**
HzAkW %
PID output in % as the maximum frequency (F03)
being at 100%
14
Load factor
50;
HzAkW %
Load factor of the motor in % as the rated output
being at 100%
15
Motor output
)85
HzAkW kW Motor output in kW 16
Analog signal input
monitor
8"00
HzAkW -
An analog input to the inverter in a format suitable
for a desired scale.
17
Current position pulse
1234
HzAkW pulse The current position pulse 21
Position error pulse
2345
HzAkW pulse The current position deviation pulse. 22
Torque current
48
HzAkW %
Torque current command value or calculated
torque current
23
Magnetic flux command
50
HzAkW %
Magnetic flux command value
(Available only under vector control)
24
Input watt-hour
10*0
HzAkW kWh
100
(kWh) hour- wattInput
value Indicated =
25
Illuminated, Not illuminated