5.3 Description of Function Codes
5-132
E44
LED monitor (display when stopped)
E44 specifies whether the specified value (data = 0) or the output value (data = 1) will be displayed on the LED
monitor of the keypad when the inverter is stopped. The monitored item depends on the E48 (LED monitor, Speed
monitor item) setting as shown below.
E48 data Monitored item
Inverter stopped
E44 = 0 Specified value E44 = 1 Output value
0 Output frequency 1
(before slip compensation)
Reference frequency Output frequency 1
(before slip compensation)
1 Output frequency 2
(after slip compensation)
Reference frequency Output frequency 2
(after slip compensation)
2 Reference frequency Reference frequency Reference frequency
3 Motor rotation speed Reference motor rotation speed Motor rotation speed
4 Load rotation speed Reference load rotation speed Load rotation speed
5 Line speed Reference line speed Line speed
6 Transport time for specified
length
Transport time for specified
length setting
Transport time for specified
length
7 Speed (%) Reference display speed Display Speed
E48
LED monitor (speed monitor item) (refer to E43)
For details about LED Monitor (Speed monitor item), refer to the description of E43.
E49
Torque Command Monitor (Polarity selection)
The polarity of calculated torque value in v/f control or the torque command value in vector control is normally + for
driving and for braking. However in the case of hoisting load, when the motor rotation direction changes from
forward direction to reverse direction, the torque polarity also changes from driving to braking. If it monitors the
torque data by FRENIC-Loader, we cannot take the expected data around zero speed because the polarity
changes. If E49 is set to 0, the torque monitor data becomes + for forward/driving and reverse/braking, - for
forward/braking and reverse/driving. Therefore we can monitor the continuous torque data around zero speed.
E49 data Torque monitor polarity
0 Torque polarity
(+ for forward/driving and reverse braking, - for forward/braking and reverse/driving)
1 (Factory setting) Plus for driving, Minus for braking
First quadrant:
Forward/Driving
Output torque
Motor speed0
Second quadrant:
Reverse/Braking
Third quadrant:
Reverse/Driving
Fourth quadrant:
Forward/Braking
First quadrant:
Forward/Driving
Output torque
Motor speed0
Second quadrant:
Reverse/Braking
Third quadrant:
Reverse/Driving
Fourth quadrant:
Forward/Braking
E49=0Torque polarity E49=1+ for driving, - for braking