9.2 CANopen Communication
9-28
Index
(Hex)
Sub Name Description Data type Data hold Access
1802
- 3rd Transmit PDO Communication Parameter RECORD - -
0 Largest sub-index Maximum sub-index No.: 5 UNSIGNED8 - R
1 COB-ID
COB-ID of TPDO No.3
Default value: 0x380 + node ID
UNSIGNED32 Y RW
*1
2 Transmission type
Select the transmission type
Default value: 255
(Change of state event)
(refer to Table 9.2-11, Table 9.2-12)
UNSIGNED8 Y RW
3 Inhibit time
Waiting time for transmission (unit: 0.1 ms)
Default value: 100 (10.0 ms)
UNSIGNED16 Y RW
*2
5 Event timer
Periodical transmission interval (unit: 1 ms)
Transmission type
Valid at the time of 254 or 255.
Default value: 0 (not used)
UNSIGNED16 Y RW
1A00
- 1st Transmit PDO Mapping Parameter RECORD - -
0
Number of mapped
objects
Number of mapped objects (up to 4)
Default value: 1
UNSIGNED8 - RW
1 PDO mapping entry1 Default value: 0x60410010 (Statusword) UNSIGNED32 - RW
2 PDO mapping entry2 Default value: No mapping UNSIGNED8 - RW
3 PDO mapping entry3 Default value: No mapping UNSIGNED8 - RW
4 PDO mapping entry4 Default value: No mapping UNSIGNED32 RW
1A01
- 2nd Transmit PDO Mapping Parameter RECORD - -
0
Number of mapped
objects
Number of mapped objects (up to 4)
Default value: 2
UNSIGNED8 - RW
1 PDO mapping entry1 Default value: 0x60410010 (Statusword) UNSIGNED32 - RW
2 PDO mapping entry2 Default value: 0x60440010 (vl control effort) UNSIGNED32 - RW
3 PDO mapping entry3 Default value: No mapping UNSIGNED8 - RW
4 PDO mapping entry4 Default value: No mapping UNSIGNED32 - RW
1A02
- 3rd Transmit PDO Mapping Parameter RECORD - -
0
Number of mapped
objects
Number of mapped objects: 4 UNSIGNED8 - R
1 PDO mapping entry1
Fixed value: 0x5F030110
(reading function code mapping 1)
UNSIGNED32 - R
2 PDO mapping entry2
Fixed value: 0x5F030210
(reading function code mapping 2)
UNSIGNED32 - R
3 PDO mapping entry3
Fixed value: 0x5F030310
(reading function code mapping 3)
UNSIGNED32 - R
4 PDO mapping entry4
Fixed value: 0x5F030410
(reading function code mapping 4)
UNSIGNED32 - R
*1: The change of COB-ID will be possible after writing one into the bit 31.
*2: The change of Inhibit timer is possible when the related PDO is invalid (COB-ID’s bit 31 is one).