12.1 Standard Model
12-13
SPECIFICATIONS
Chap 12
Standard-model, Three-phase 200 V (230 V) class series (HHD-mode: 5.5 kW to 22 kW)
Item Specifications
Type (FRN_ _ _ _E2S-2) 0030 0040 0056 0069 0088 0115
Nominal applied motor (kW) [HP]
(Output rating)
*1
5.5
[7.5]
7.5
[10]
11
[15]
15
[20]
18.5
[25]
22
[30]
Output ratings
Rated capacity (kVA) *2
9.5
[10]
13
[13]
18
[19]
23
[24]
29
[30]
34
[36]
Rated voltage (V) *3 Three-phase 200 to 240 V (with AVR function)
Rated current (A) *4 25 33 47 60 76 90
Overload capability 150%-1 min, 200%-0.5 s
Input power
Voltage, frequency Three-phase 200 to 240 V, 50/60 Hz
Allowable voltage/frequency
Voltage: +10 to -15% (Interphase voltage unbalance: 2% or less) *6,
Frequency: +5 to -5%
Rated input current *7
(w/o DCR) (A)
31.5 42.7 60.7 80.0 97.0 112
(with DCR) (A) 21.1 28.8 42.2 57.6 71.0 84.4
Required capacity
(with DCR) (kVA) *8
7.3 10 15 20 25 30
Braking
Torque (%)
*9
20%
DC braking
Braking starting frequency: 0.0 to 60.0 Hz, Braking time: 0.0 to 30.0 s,
Braking level: 0 to 100%
Braking transistor Built-in as standard
Minimum resistance value (Ω)
20 15 10 8.6 4
Braking resistor Separately mounted option
DC reactor (DCR) Separately mounted option
Applicable safety standards IEC/EN61800-5-1: 2007
Enclosure (IEC60529) IP20, UL open type
Cooling method Fan cooling
Weight / Mass (kg) [lbs]
5.0
[11]
5.0
[11]
8.0
[18]
9.0
[20]
9.5
[21]
10
[22]
Note: A box () in the above table replaces GA, GB or C depending on the model.
*1 Fuji 4-pole standard motor
*2 Rated capacity is calculated assuming the rated output voltage as 220 V (230 V).
*3 Output voltage cannot exceed the power supply voltage.
*4 Setting the carrier frequency (F26) to the following value or above requires current derating.
HHD spec. of types FRN0030E2■-2 to FRN0115E2■-2: 10 kHz
If reduction is necessary, for details, refer to Figure 10.4-1 in Chapter 1010.4.2 Guideline for selecting
inverter drive mode and capacity.
*6
67 ×
(V) voltage average phase-Three
(V) voltage Min. - (V) voltage Max.
=(%) unbalance Voltage
(IEC 61800-3)
If the unbalance ratio is 2% to 3%, use an optional AC reactor (ACR).
*7 This specification is an estimated value to be applied when the power supply capacity is 500 kVA (Inverter
capacity × 10 when the capacity exceeds 50 kVA) and the power supply with %X = 5% is connected.
*8 This specification applies when a DC reactor (DCR) is used.
*9 Average braking torque for the motor running alone. It depends on the efficiency of the motor.