5 Tools
224
Tools
5
Example: To save in the bbb directory under the aaa directory in the root directory.
aaa/bbb
z
Forwarding via SMB
Example: To save in the bbb directory under the aaa directory in a specified volume.
aaa\bbb
User Name
When a user name is required to be input by the forwarding destination server, set the user
name.
When [FTP] is selected under [Transfer Protocol], up to 32 characters are allowed.
When [SMB] is selected under [Transfer Protocol], use one of the following formats.
z
For Active Directory:
User name@Domain name (User name: up to 32 characters / Domain name: up to 64
characters)
Example: fuji@example.com (fuji: user name / example.com: domain name)
z
For Windows NT domains:
Domain name\User name (Domain name: up to 64 characters / User name: up to 32
characters)
Example: example\fuji (example: domain name / fuji: user name)
z
For workgroups:
Local user (up to 32 characters)
Example: Fuji-Taro
Password
When a password entry is prompted by the forwarding destination server, specify a
password. You can enter up to 32 characters for a password.
Port Number
Set the forwarding destination port number. Specify a number in the range from 1 to 65535.
Index
You can enter a single alphanumeric index character for use as a keyword to search the
address book.
For information about how to enter characters, refer to "Entering Text" (P.27).
Relay Station Setup
When the machine is used as a relay station in a relay broadcast, select whether or not to
certify the registered address number as an initiating station for the relay broadcast.
When performing the relay broadcast, the initiating station must be registered to an address
number in the relay station regardless of the instruction method.
Starting Rate
Set the communications mode. You can select [G3 Auto] or [Forced 4800 bps].
When the destination is specified by an address book entry with the communications mode
set, it is not possible to change the communications mode in the [Fax/Internet Fax] screen.
Note • [G4 Auto] appears when an Internet Fax Kit is installed. For iFax, the setting applies to the
section between the fax gateway and the recipient fax.
Resolution
Set the transmission image quality.
Select from [Panel] (image quality selected on the control panel), [Standard (200x100 dpi)],