FC2250-UM-251-9370 8-21
8. ELECTRICAL ADJUSTMENTS
(16) Ifyouhavechangedthediagonaldistancevalue,conrmtheaxisdistance.
Load a new sheet of paper and press the [F2] key to draw the adjusted test pattern.
Measureeachdistance.Ifthemeasuredvaluesarewithinthespecicationrange,pressthe[ENTER]
key to store the setting.
SpecicationrangefortheXdistance=500mm±0.2mm.
SpecicationrangefortheYdistance=700mm±0.2mm.
Specicationrangeforthediagonaldistance=within0.1mmfromthedisplayedLvalue.
Ifthemeasuredvalueisoutsidethespecicationrange,adjustagainfromstep(7).
(17) When the adjustment is complete, turn off the power to the plotter.
(18) Return the DIP switch to its default settings (see subsection 8.5 “Setting the DIP Switches”).