Program description - Control adjust | Winged models
0%
0%
0%
–––
0%
–––
–––
–––
GL
GL
GL
GL
normal
fr
fr
fr
3
In5
offset
In6
In7
In8
typ
Now put the 3-way switch back into its middle posi-
tion. Move the marker frame as necessary to the left
into the column labelled with the new switch symbol,
briefly tap on the centre SET key of the right four-way
button then assign the switch’s other switch direction
by once again starting from the middle position but this
time move the switch in the other direction.
The display will now present the given switch number
together with a symbol indicating the given switch
direction, for example:
0%
0%
0%
–––
0%
–––
–––
GL
GL
GL
GL
normal
fr
fr
fr
3
2
In5
offset
In6
In7
In8
typ
Tips:
When assigning switches, pay attention to
the desired switching direction and also
that all unused inputs remain “free” or are
again reset to “free”. This is necessary to ensure
that inadvertent actuations of these unused con-
trols cannot cause malfunctions.
The travel setting described below allows the ap-
propriate end state to be established for an as-
signed switch.
Erasing a transmitter control or switch assignment
A simultaneous tap on the  or  keys of the right
four-way button (CLEAR) while on an input line with
an active transmitter control or switch assignment see
above figures will reset the given input back to “fr” and
“---”.
Column 4, “offset”
The control centre for the given control, i. e. its zero
point, can be changed in this column. The adjustment
range lies between -125 % and +125 %.
0%
0%
0%
–––
0%
–––
–––
GL
GL
GL
GL
normal
fr
fr
fr
3
2
In5
offset
In6
In7
In8
typ
A simultaneous tap on the  or  keys of the right
four-way button (CLEAR) will reset the entry field value
displayed in inverse video back to “0 %”.
Column 5, “– travel +”
The “-Travel+” column is accessed by using the Select
button of the left or right-hand four-way button to
shift the marker frame to the right, beyond the “Offset”
column, as indicated by the right-pointing arrow at bot-
tom left of the screen.
This column is used to set servo travel symmetrically
or asymmetrically for each side. The setting range is
±125 % of normal servo travel.
Select an input, 5 through 8 or 5 through 12, with the
 selection keys of the left or right four-way button.
To set symmetric travel, i. e. control-side independent
travel, the respective operating element (transmitter
control or switch) is to be put into a position in which
the travel setting will be covered on both sides by the
marker frame:
– travel +
+100%
+100%
+100%
+100%
+100%
+100%
+100%
+100%
normal
In5
In6
In7
In8
To set asymmetric travel, the respective operating
element (transmitter control or switch) is to be moved
to the side to be set such that the marker frame only
includes the value to be changed:
+100%
+100%
+100%
+100%
+100%
+100%
+100%
+100%
normal
– travel +
In5
In6
In7
In8
The value setting is activated by briefly touching the
centre SET key of the right four-way button. The value
field/s will be displayed in inverse video. Values can be
changed with the selection keys of the right four-way
button:
+100%
+100%
+100%
+100%
+100%
+100%
normal
+111%
+111%
– travel +
In5
In6
In7
In8

Table of Contents

Other manuals for GRAUPNER mc-16

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GRAUPNER mc-16 and is the answer not in the manual?

GRAUPNER mc-16 Specifications

General IconGeneral
BrandGRAUPNER
Modelmc-16
CategoryRemote Control
LanguageEnglish

Related product manuals