CD Player and Air Conditioning System-6
Turn the ignition switch from OFF to ON
The display symbols all light up
failure of the switch or display tune
NO
Press down Temp+”
switch
Enter into self-diagnosis procedur1?
NO
Temp +” switch failure
Step 1:
Display 01”
(set the temperature zone)
all other display symbols turn of
f
Press down
“Temp+” switch
Step 2: Display
“02”(set the
temperature
zone)
The inspection procedures
During the period of 10 seconds after the engine is started(turn the ignition switch from OFF to ON), press OF F, A U TO,
RR and MODE once more, and the pressing of MODE switch shall last at least 2 seconds
.
All sensors are good.
Display
“000”(outsidetemperature)