CD Player and Air Conditioning System-7
Code of failure Sensor failure
100 Open circuit of outside temperature sensor
200 Short circuit of outside temperature sensor
010 Open circuit of inside temperature sensor
020 short circuit of inside temperature sensor
001 Open circuit of temperature sensor of the evaporator
002 Short circuit of temperature sensor of the evaporator
Step 3: Display “03”(set the temperature zone)
Display the outside temperature value
Press down “Temp+” switch
Step 4: Display “04”(set the temperature zone
)
Sensor failure
The code of the sensor with failure
is showed on the display screen
.
Press down “Temp+” switch
Press down
“Temp+” switch
Step 5:
Display “05”
(set the temperature zone)
Display the inside temperature value
Display the temperature value of the evaporator
Press down
“Temp+” switch