165
_____________________________________________________________________________________________
10.2 Command Table
______________________________________________________________________________________________
:WITHstand:DTIMer?
Queries the ramp-down time ON/OFF for withstand-voltage tests. 182
:MEASure:RESult:WITHstand? Queries the withstand-voltage test result. 183
:MEASure:WITHstand:VOLTage?
Queries the measured voltage value for withstand-voltage tests. 183
:MEASure:WITHstand:CURRent? Queries the measured current value for withstand-voltage tests. 184
:MEASure:WITHstand:TIMer?
Queries the test time elapsed for withstand-voltage tests. 184
:MEMory:WITHstand:FILE? Queries the contents of the set-value memory for withstand-
voltage tests.
185
:MEMory:WITHstand:LOAD Loads the set-value memory for withstand-voltage tests. 185
:MEMory:WITHstand:SAVE
Saves set values for withstand-voltage tests in memory. 186
:MEMory:WITHstand:CLEar Clears the set-value memory for withstand-voltage tests. 186
:CONFigure:INSulation:VOLTage
Sets the test-voltage value for insulation-resistance tests. 186
:CONFigure:INSulation:VOLTage? Queries the test-voltage value for insulation-resistance tests. 187
:CONFigure:INSulation:RUPPer
Sets the upper-limit value for insulation-resistance tests. 187
:CONFigure:INSulation:RUPPer? Queries the upper-limit value for insulation-resistance tests. 187
:CONFigure:INSulation:RLOWer
Sets the lower-limit value for insulation-resistance tests. 188
:CONFigure:INSulation:RLOWer? Queries the lower-limit value for insulation-resistance tests. 188
:CONFigure:INSulation:TIMer
Sets the test time for insulation-resistance tests. 188
:CONFigure:INSulation:TIMer? Queries the test time for insulation-resistance tests. 189
:CONFigure:INSulation:DELay
Sets the delay time for insulation-resistance tests. 189
:CONFigure:INSulation:DELay? Queries the delay time for insulation-resistance tests. 189
:INSulation:RUPPer
Enables and disables the upper-limit value for insulation-
resistance tests.
190
:INSulation:RUPPer?
Queries the upper-limit value enablement for insulation-
resistance tests.
190
:INSulation:TIMer
Enables and disables the test time for insulation-resistance tests. 190
:INSulation:TIMer? Queries the test time enablement for insulation-resistance tests. 191
:INSulation:DELay
Sets the delay time ON/OFF for insulation-resistance tests. 191
:INSulation:DELay? Queries the delay time ON/OFF for insulation-resistance tests. 191
:MEASure:RESult:INSulation?
Queries the insulation-resistance test result. 192
:MEASure:INSulation:VOLTage? Queries the measured voltage value for insulation-resistance
tests.
192
:MEASure:INSulation:RESistance? Queries the measured resistance value for insulation-
resistance tests.
193
:MEASure:INSulation:TIMer? Queries the test time elapsed for insulation-resistance tests. 193
:MEMory:INSulation:FILE?
Queries the content of data saved for insulation-resistance tests. 194
:MEMory:INSulation:LOAD Loads data saved for insulation-resistance tests. 194
:MEMory:INSulation:SAVE
Saves data for insulation-resistance tests to memory files. 195
:MEMory:INSulation:CLEar Clears the insulation-resistance test data saved to memory files. 195
:PROGram:EDIT:FILE
Sets the file scanner mode for program tests. 196
:PROGram:EDIT:FILE? Queries the file scanner mode for program tests. 196
:PROGram:EDIT:STEP
Makes settings for the scanner, test mode, and test
conditions for program test step.
197
:PROGram:EDIT:STEP?
Queries settings for the scanner, test mode, and test
conditions for program test step.
198
:PROGram:LOAD:FILE
Loads the program test file. 199
:MEASure:RESult:FILE? Queries the test result of the program test file. 199
:MEASure:RESult:STEP?
Queries the measured result in the program test step. 200