Malfunction, cause and remedy 17
Faults of the electrics/electronics 17.5
Comprima V 180
Original Operating Instructions 150001053_00_en 217
Possible cause Remedy
FMI 7: The net has not been cut. The net is not cleanly cut.
The cutting unit is blunt.
Remove deposits from the cutting unit.
Replace the cutting unit.
The cutting unit is not
clamped.
Remove deposits from the cutting unit.
Check and set the cutting position, refer to page137.
The actuator for wrapping pro-
cess is defective.
Check the actuator for wrapping process.
The ratchet on the cutting unit
does not move upwards.
Check the wire rope on the cutting unit and, if required,
shorten.
522024-
Chamber film wrapping
Possible cause Remedy
FMI 7: The film was not cut off. The film is not cut off neatly.
The cutting unit is blunt.
Remove deposits from the cutting unit.
Replace the cutting unit.
The cutting unit is not
clamped.
Remove deposits from the cutting unit.
Check and set the cutting position, refer to page137.
The actuator for wrapping pro-
cess is defective.
Check the actuator for wrapping process.
The ratchet on the cutting unit
does not move upwards.
Check the wire rope on the cutting unit and, if required,
shorten.
522035-
MAX
Filling the bale chamber
Possible cause Remedy
FMI 0: The maximum filling of the bale chamber has been reached. The round bale is forcibly
tied, even if it should be manually tied. This may damage the machine in the long term.
Too many crops loaded too
quickly into the bale chamber.
Reduce the driving speed earlier and adjust to the swath.
Advance signalling has not
been set.
Set advance signalling, refer to page119.
Advance signalling has been
ignored and the bale chamber
loaded with too many crops.
Observe advance signalling.
Do not permanently overload the bale chamber.
522038-
Bale chamber bale formation conveyor
Possible cause Remedy
FMI 1: The setpoint speed of the bale formation conveyor of the bale chamber was below the
minimum.
The bale formation conveyor
is rotating slower than it
should. Slippage is occurring.
Reduce the baling pressure.
Check and set the sensorB01 "Speed of bale chamber",
refer to page202.
Check and set the sensorB05 "Slip floor conveyor", refer to
page202.
Very heavy and/or wet crops
are being loaded.

Table of Contents