2MN/2N1-1
1-3-59
U106 Setting: [Bias]
1. Select the item to be set.
2. Change the value using the numeric keys.
*: 55 ppm model only.
3. Press the OK key. The value is set.
Completion
Press the Back key. The screen for selecting a maintenance item No. is displayed.
Item No. Description
Display Description
Setting
range
Initial setting
45ppm 55ppm
Reverse Transfer reverse bias
(full speed)
0 to 255 1 1
Reverse
Half
Transfer reverse bias
(half speed)
0 to 255 1 1
Reverse
3/4
Transfer reverse bias at 3/4
times of line speed
0 to 255 1 1
Reverse
B/W*
Transfer reverse bias in
black/white mode
0 to 255 - 1
Cleaning Cleaning control value
(full speed)
0 to 255 138 143
Cleaning
Half
Cleaning control value
(half speed)
0 to 255 126 130
Cleaning
3/4
Cleaning control value at 3/4
times of line speed
0 to 255 133 133