2MN/2N1-1
1-3-115
U345 Setting the value for maintenance due indication
Description
Sets when to display a message notifying that the time for maintenance is about to be reached,
by setting the number of prints that can be made before the current maintenance cycle ends.
When the difference between the number of prints of the maintenance cycle and that of the main-
tenance count reaches the set value, the message is displayed.
Purpose
To change the time for maintenance due indication.
Setting
1. Press the OK key.
2. Change the setting using the numeric keys.
3. Press the OK key. The value is set.
Completion
Press the Back key. The screen for selecting a maintenance item No. is displayed.
U410 Setting a Gamma table
Description
Setting a Gamma table.
Purpose
Setting a Gamma table.
Method
1. Press the OK key.
2. Select the item to set.
Completion
Press the Back key. The screen for selecting a maintenance item No. is displayed.
Item No. Description
Display Description
Setting
range
Initial
setting
Cnt Time for maintenance due indication
(Remaining number of prints that can be made
before the current maintenance cycle ends)
0 to 9999 0
Display Description
Table1 Gamma table1
Table2 Gamma table2
Table3 Gamma table3