2MN/2N1
1-3-82
U157 Checking the developer drive time
Description
Displays the developer drive time for checking a figure, which is used as a reference when cor-
recting the toner control.
Purpose
To check the developer drive time after replacing the developer unit.
Method
1. Press the OK key. The developer drive time is displayed.
Completion
Press the Back key. The screen for selecting a maintenance item No. is displayed.
U158 Checking the developer count
Description
Displays the developer count for checking.
Purpose
To check the developer unit status.
Method
1. Press the OK key. The current developer counts is displayed.
Completion
Press the Back key. The screen for selecting a maintenance item No. is displayed.
Item No. Description
Display Description
C Developer drive time for cyan
M Developer drive time for magenta
Y Developer drive time for yellow
K Developer drive time for black
Display Description
C Developer count value for cyan
M Developer count value for magenta
Y Developer count value for yellow
K Developer count value for black