9/12/00 B-15
An indicator has been added to the ON display on the top
line of the 824’s display to show faults that were detected by
the power on test procedure. The R151 command will dis-
play the fault character to a computer.
R138 SSA, LOG Interval Date and Time of Occur-
rence
ddmmmyy hh:mm:ss
R139 SSA, LOG Interval Duration hh:mm:ss / mm:ss.ss
R140 SSA, LOG Interval Lint nnn.n dB
R141 SSA, LOG Interval SEL nnn.n dB
R142 SSA, LOG Interval Lmin nnn.n dB
R143 SSA, LOG Interval Lmax nnn.n dB
R144 SSA, LOG Interval Lpeak nnn.n dB
R145 SSA, LOG Interval UnWeighted Peak nnn.n dB
R146 SSA, LOG AUTO-SEND HISTORY LEQ nnn.n dB
R150 ALL Number of RUNS & CONTINUES nnnnn
R151 ALL Power On Fault Cause Character
D - Data Checksum Corrupt
E - EEPROM Checksum Corrupt
K - Key Reset (



+ l+ v)
P - setting Checksum Corrupt
O - Opcode Error
R - RAM Setup Register Corrupt
T - Test Memory Corrupt
W - Watchdog Reset
c
R152 ALL Internal RMS detector level nnn.nn dB
R153 ALL Internal PEAK detector level nnn.nn dB

Table of Contents

Other manuals for Larson Davis System 824

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Larson Davis System 824 and is the answer not in the manual?

Larson Davis System 824 Specifications

General IconGeneral
BrandLarson Davis
ModelSystem 824
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals