EasyManua.ls Logo

Lenovo ThinkServer RD650 - Controller Show Commands

Lenovo ThinkServer RD650
418 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
LSI Corporation
- 164 -
12Gb/s MegaRAID SAS Software User Guide
March 2014
Chapter 6: StorCLI
Working with the Storage Command Line Tool
6.6.2.2 Controller Show Commands
The Storage Command Line Tool supports the following show commands:
storcli /cx show
storcli /cx show all
storcli /cx show freespace
dimmerswitch|ds See Dimmer Switch Commands. See Dimmer Switch Commands.
foreignautoimport on|off Imports foreign configuration automatically, at
boot.
jbod on|off Enables/disables JBOD mode; by default, drives
become system drives.Not supported by all
controllers.
loadbalancemode on|off Enables/disables automatic load balancing
between SAS phys or ports in a wide port
configuration.
maintainpdfailhistory on|off Maintains the physical drive fail history.
migraterate 0 to 100 Sets data migration rate in percentage.
patrolread|pr See Patrol Read. See Patrol Read.
perfmode 0: Tuned to provide best IOPS, currently
applicable to non-FastPath
1: Tuned to provide least latency, currently
applicable to non-FastPath
Performance tuning setting for the controller.
pi on|off Enables/disables data protection on the
controller.
pi import on|off Enables/disables import data protection drives
on the controller.
prcorrectunconfiguredareas on|off Correct media errors during PR by writing 0s to
unconfigured areas of the disk.
prrate 0 to 100 Sets patrol read rate of the virtual drives in
percentage.
rebuildrate 0 to 100 Sets rebuild rate of the drive in percentage.
reconrate 0 to 100 Sets reconstruction rate for a drive in percentage.
restorehotspare on|off Becomes a hot spare on insertion of a failed
drive.
smartpollinterval 0 to 65535 Set time for polling of SMART errors in seconds.
spinupdrivecount 0 to 255 Sets number of drives that are spun up at a time.
spinupdelay 0 to 255 Sets spin-up delay between a group of drives or a
set of drives, in seconds.
stoponerror on|off Stops the MegaRAID BIOS during POST, if any
errors are encountered.
time Valid time in yymmdd hh:mm:ss format
or systemtime
Sets the controller time to your input value or the
system time (local time in 24-hour format).
usefdeonlyencrypt on|off Enables/disables FDE drive-based encryption.
DPM on|off Enables/disables drive performance monitoring
supportssdpatrolread on|off Enables/disables patrol read for SSD drives.
SGPIOforce on|off Force SGPIO status per port only for four drives;
affects HPC controllers.
Property Name Set Command Range Description

Table of Contents

Other manuals for Lenovo ThinkServer RD650

Related product manuals