EasyManua.ls Logo

Lenovo ThinkServer RD650 - Appendix A: Events and Messages

Lenovo ThinkServer RD650
418 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
LSI Corporation
- 355 -
12Gb/s MegaRAID SAS Software User Guide
March 2014
Appendix A: Events and Messages
Appendix A: Events and Messages
This appendix lists the MegaRAID Storage Manager events that can appear in the event log.
MegaRAID Storage Manager software monitors the activity and performance of all controllers in the workstation and
the devices attached to them. When an event occurs, such as the start of an initialization, an event message appears in
the log at the bottom of the MegaRAID Storage Manager main menu window. The messages are also logged in the
Windows Application log (Event Viewer).
A.1 Error Levels
Each message that appears in the event log has a Severity level that indicates the severity of the event, as shown in
the following table.
Table 56 Event Error Levels
A.2 Event Messages
The following table lists all of the MegaRAID Storage Manager event messages. The event message descriptions
include placeholders for specific values that are determined when the event is generated. For example, in message
No. 1 in the Event Messages table, “%s” is replaced by the firmware version, which is read from the firmware when the
event is generated.
Table 57 Event Messages
Severity Level Meaning
Information Informational message. No user action is necessary.
Warning Some component might be close to a failure point.
Critical A component has failed, but the system has not lost data.
Fatal A component has failed, and data loss has occurred or will occur.
Number
Severity
Level
Event Text Generic Conditions when Each Event Occurs
0x0000 Information MegaRAID firmware initialization
started (PCI ID
%04x/%04x/%04x/%04x)
Logged at firmware initialization.
0x0001 Information MegaRAID firmware version %s Logged at firmware initialization to display firmware version.
0x0002 Fatal Unable to recover cache data from
TBBU
Currently not logged.
0x0003 Information Cache data recovered from TBBU
successfully
Currently not logged.
0x0004 Information Configuration cleared Logged when controller configuration is cleared.
0x0005 Warning Cluster down; communication with
peer lost
Currently not logged.
0x0006 Information Virtual drive %s ownership changed
from %02x to %02x
Currently not logged.
0x0007 Information Alarm disabled by user Logged when user disables alarm.
0x0008 Information Alarm enabled by user Logged when user enables alarm.