12Gb/s MegaRAID SAS Software User Guide
March 2014
Appendix A: Events and Messages
0x0009 Information Background initialization rate
changed to %d%%
Logged to display background initialization progress
indication in percentage.
0x000a Fatal Controller cache discarded due to
memory/battery problems
Logged on cache discard due to hardware problems.
0x000b Fatal Unable to recover cache data due to
configuration mismatch
Currently not logged.
0x000c Information Cache data recovered successfully Logged when cache data is successfully recovered after
reboot.
0x000d Fatal Controller cache discarded due to
firmware version incompatibility
Logged when cache data discarded because of firmware
version mismatch.
0x000e Information Consistency Check rate changed to
%d%%
Logged to display Consistency check progress indication
percentage.
0x000f Fatal Fatal firmware error: %s Logged in case of fatal errors and also while entering debug
monitor.
0x0010 Information Factory defaults restored Logged while controller is reset to factory defaults.
0x0011 Information Flash downloaded image corrupt Logged to inform downloaded flash image is corrupt.
0x0012 Critical Flash erase error Logged in case of flash erase failure, generally after flash
update.
0x0013 Critical Flash timeout during erase Logged to indicate flash erase operation timed out.
0x0014 Critical Flash error Generic unknown internal error during flash update flash.
0x0015 Information Flashing image: %s Logged to display flash image name string before getting
updated to controller.
0x0016 Information Flash of new firmware images
complete
Logged to inform successful update of flash image(s).
0x0017 Critical Flash programming error Logged to notify, write failure during flash update, not being
allowed usually due to internal controller settings.
0x0018 Critical Flash timeout during programming Logged to indicate flash write operation timed out.
0x0019 Critical Flash chip type unknown Logged during flash update tried with unsupported flash
chip type.
0x001a Critical Flash command set unknown Logged while unsupported flash command set detected,
most likely because of unsupported flash chip.
0x001b Critical Flash verify failure Logged when compare operation fails between written flash
data and original data.
0x001c Information Flush rate changed to %d seconds Logged to notify modified cache flush frequency in seconds.
0x001d Information Hibernate command received from
host
Logged to inform about reception of hibernation command
from host to controller, generally during host shutdown.
0x001e Information Event log cleared Logged when controller log has been cleared.
0x001f Information Event log wrapped Logged when controller log has been wrapped around, when
the maximum logs are written.
0x0020 Fatal Multi-bit ECC error: ECAR=%x,
ELOG=%x, (%s)
Logged to notify ECC multi bit error in memory, ELOG: ecc
info (source, type, syndrome), ECAR:ecc address.
0x0021 Warning Single-bit ECC error: ECAR=%x,
ELOG=%x, (%s)
Logged to notify ECC single bit error in memory, ELOG: ecc
info (source, type, syndrome), ECAR:ecc address.
0x0022 Fatal Not enough controller memory Logged to notify fatal controller condition, when you run out
of memory to allocate.
0x0023 Information Patrol Read complete Logged when patrol read completes.
0x0024 Information Patrol Read paused Logged when patrol read is paused.
Number
Severity
Level
Event Text Generic Conditions when Each Event Occurs