Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23 101
4 Device control (DCTRL)
4.1 Device commands (C00002/x)
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Activate device command
When an online connection has been established, simply use the »Engineer« to activate a device
command by selecting the corresponding option from the Parameters tab in C00002/x
("0: off" or
"1: On / start").
Alternatively, the device command can also be activated via e.g. keypad or through a master
control by writing to C00002/x
.
Some of the frequently used device commands (such as "Save parameter set") can also be
executed via the Toolbar icons of the »Engineer« when an online connection has been
established:
Symbol Function
Enable inverter
Inhibit inverter
Save parameter set (for 8400: Save all parameter sets)
Note!
Device commands that can be executed via the Toolbar of the »Engineer« always affect
the element currently selected in the Project view including all subelements!
•If no inverter but a system module is selected in the Project view, the corresponding
device command will be activated in all lower-level inverters having an online
connection with the »Engineer«.
Before the desired action is carried out, a confirmation prompt appears first, asking
whether the action is really to be carried out.