Parameter | Name:
C00976 | VFC-ECO: Ti CosPhi controller
Data type: UNSIGNED_16
Index: 23599
d
= 5C2F
h
From version 10.00.00
Reset time of the Cos-Phi controller for energy-saving V/f characteristic control (VFCplusEco
)
Setting range (min. value | unit | max. value) Lenze setting
0.0 ms 6000.0 200.0 ms
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10
Parameter | Name:
C00977 | VFC-ECO: Minimum voltage V/f
Data type: INTEGER_16
Index: 23598
d
= 5C2E
h
From version 10.00.00
Minimum voltage V/f of the Cos-Phi controller for energy-saving V/f characteristic control (VFCplusEco
)
Setting range (min. value | unit | max. value) Lenze setting
20.00 % 100.00 20.00 %
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00978 | VFC-ECO: Voltage reduction
Data type: INTEGER_16
Index: 23597
d
= 5C2D
h
From version 10.00.00
Display of the voltage reduction with energy-saving V/f characteristic control (VFCplusEco
)
Display range (min. value | unit | max. value)
-1000 V 1000
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00979 | Cosine phi
Data type: INTEGER_16
Index: 23596
d
= 5C2C
h
From version 10.00.00
Display of the cosϕ setpoint and actual value with energy-saving V/f characteristic control (VFCplusEco
)
Display range (min. value | unit | max. value)
-1.00 1.00
Subcodes Info
C00979/1 Cosine phi act
C00979/2 Cosine phi set
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100