Loading...
15 Parameter reference
15.2 Parameter list
1142
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02817
C02830
Parameter | Name:
C02817 | TP: TouchProbe position
Data type: INTEGER_32
Index: 21758
d
= 54FE
h
From version 06.00.00
Touch-probe detection
Display range (min. value | unit | max. value)
-214748.3647 units 214748.3647
Subcodes Info
C02817/1 Reserved
C02817/2 Reserved
C02817/3 TPDigIn3: TP position
C02817/4 TPDigIn4: TP position
C02817/5 TPDigIn5: TP position
C02817/6 TPDigIn6: TP position
C02817/7 TPDigIn7: TP position
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10000
Parameter | Name:
C02830 | DIx: Debounce time
Data type: UNSIGNED_8
Index: 21745
d
= 54F1
h
Debounce times for the digital inputs
Digital input terminals

Table of Contents