15 Parameter reference
15.2 Parameter list
1148
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02865
Bit 11 Latching of open circuit FreqIn12 or
67
Bit 12 SLVC: No smoothing of
nMotorTorqueAct_a
Bit 13 SLVC: Setpoint feedforward control is
active
Bit 14 Reserved
Bit 15 Reserved
Subcodes Lenze setting Info
C02864/1 0x0000 MCTRL
: Optimisations
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C02864 | MCTRL: Optimisiations
Data type: UNSIGNED_16
Index: 21711
d
= 54CF
h
Parameter | Name:
C02865 | MCTRL: Special settings
Data type: UNSIGNED_16
Index: 21710
d
= 54CE
h
From version 12.00.00
Activation of special functions of the internal motor control
Setting range (min. hex value | max. hex value)
0x0000 0xFFFF
Value is bit-coded: Info
Bit 0 No TorqueLimit if TorquemodeOn From version 12.00.00 onwards: If sensorless vector
control (SLVC
) or servo control (SC) are used, in the
"torque control with speed limitation" mode the torque
limitation via nTorqueMotLimit_a and
nTorqueGenLimit_a is also active to limit the torque
setpoint.
If you want to deactivate the torque limitation to retain
the former function, set bit 0 to "1".
0 Torque limitation is active
1 Torque limitation is not active
Bit 1 250ms IMP before DCB
Bit 2 1000ms IMP before DCB
Bit 3 DCB: Current controller and C036
app. to C088
Bit 4 Motorident.: No calculation C73 C75
C76 C77 C78
From version 12.00.00 onwards: Following successful
motor parameter identification, the current controller
and field controller parameters are calculated as well.
If these parameters are not to be calculated, bit 4 must
be set to "1".
0 Calculate parameter
1 Do not calculate parameter
Automatic motor data identification
Bit 5 Motorident.: Calculation C70 C71
C72
From version 12.00.00 onwards: Following successful
motor parameter identification, the speed controller
parameters can automatically be calculated as well.
If these parameters are to be calculated, bit 5 must be set
to "1".
0 Do not calculate parameter
1 Calculate parameter
Automatic motor data identification