15 Parameter reference
15.2 Parameter list
1150
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02867
Subcodes Lenze setting Info
C02866/1 1: Yes Motor ident.: Current controller par. from C075 C076
From version 06.00.00
Automatic motor data identification
C02866/2 0: No Motor phase error monitoring before operation
From version 11.00.00
Motor phase error monitoring before operation
C02866/3 0: No Brake chopper DC-bus slave
From version 12.00.00
Control of multiple internal brake choppers in the DC-
bus system
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C02866 | MCTRL: Special settings
Data type: UNSIGNED_8
Index: 21709
d
= 54CD
h
Parameter | Name:
C02867 - Identification procedure
Data type: UNSIGNED_8
Index: 21708
d
= 54CC
h
From version 10.00.00
Selection of the identification procedure for motor parameter identification
Automatic motor parameter identification
Selection list Info
0 automatic Automatic selection of the optimum identification
procedure:
For synchronous motors, the extended identification
procedure is always used.
For asynchronous motors with a rated motor power
of up to 11 kW, the basic identification procedure is
used.
For asynchronous motors with a rated motor power
of more than 11 kW, the extended identification
procedure is used.
1 standard identification Only for asynchronous motors.
Duration approx. 30 s
2 extended identification Stands out due to increased accuracy of the
determined motor parameters.
Also supports synchronous motors and asynchronous
motors with a power of more than 11 kW.
Duration approx. 80 s
Subcodes Lenze setting Info
C02867/1 0: automatic Motor parameter identification: Process
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1