C00185
C00186
C00187
C00188
Parameter | Name:
C00185 | AutoFailReset remaining time
Data type: UNSIGNED_16
Index: 24390
d
= 5F46
h
Display of the residual runtime of the "AutoFailReset" function
AutoFailReset function
Display range (min. value | unit | max. value)
0 s 600
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00186 | Max. number of AutoFailReset processes
Data type: UNSIGNED_8
Index: 24389
d
= 5F45
h
Maximum number of "AutoFailReset" procedures
AutoFailReset function
Setting range (min. value | unit | max. value) Lenze setting
1164
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00187 | Current AutoFailReset processes
Data type: UNSIGNED_8
Index: 24388
d
= 5F44
h
Data of the current number of "AutoFailReset" procedures
AutoFailReset function
Display range (min. value | unit | max. value)
0 16
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00188 | AutoFailReset configuration
Data type: UNSIGNED_8
Index: 24387
d
= 5F43
h
Setting which error messages are to be reset automatically.
AutoFailReset function
Selection list (Lenze setting printed in bold) Info
0Off No automatic error message reset
1 Fault + TroubleQSP Error messages with the response "Fault" and
"TroubleQSP" are reset automatically
2 WarningLocked Error messages with the response "WarningLocked" are
reset automatically
3 All locking All "locking" error messages are reset automatically
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1